Speciality Cables
Uninyvin Speciality Cable
Designed for UPS/inverter equipment, battery interlinks and protected high-temperature wiring.
Hot-dipped annealed tinned copper, flexible stranded constructionHeat-resistant PVC (HR-PVC)Core and conductor-size options to suit the application
PRODUCT OVERVIEW
Engineering Overview
Specialised single-core cable engineered with high-conductivity annealed tinned copper (ATC) conductors, heat-resistant primary dielectric insulation, protective woven braid, and protective lacquer finish for enhanced mechanical toughness and surface endurance in protected equipment leads and high-temperature applications.
Flexible stranded hot-dipped annealed tinned copper conductors are insulated with heat-resistant PVC (HR-PVC). Outer protection is glass-fibre braid with transparent nylon sheath for U22–U12; glass-fibre and nylon braid with lacquer finish for U10–U0000.
Manufactured with high-conductivity annealed tinned copper conductors for dependable electrical transmission and stable thermal performance up to 105°C. Rated for 600 V AC nominal operation; technical particulars and configuration schedules confirmed via project-specific Guaranteed Technical Particulars (GTP).
Technical Specifications
| Conductor | Hot-dipped annealed tinned copper, flexible stranded construction |
|---|---|
| Insulation | Heat-resistant PVC (HR-PVC) |
| Outer protection | Glass-fibre braid with transparent nylon sheath for U22–U12; glass-fibre and nylon braid with lacquer finish for U10–U0000 |
| Nominal voltage | 600 V AC (rms) |
| Operating temperature | −35°C to +105°C |
| Core construction | Single-core (1 conductor) |
| Conductor sizes | U22 to U0000: 0.347 to 109 mm² |
| Typical applications | UPS/inverter equipment, battery interlinks and protected high-temperature wiring. |
| Minimum bending radius | 12 × finished cable diameter |
| Voltage test | 1,500 V AC |
ENGINEERED ARCHITECTURE
Engineered Layer by Layer
Schematic layer sequence • Not to scale
Hover layer to inspect
Hover layer to inspect
01
Conductor
Annealed tinned copper, flexible stranded construction
02
Primary insulation
HR PVC for 105°C duty
03
Primary braid
Glass-fibre braid, coverage per approved gauge schedule
04
Secondary braid
Natural-white nylon braid for double-braid variant
05
Lacquer
Compatible protective lacquer finish for abrasion and chemical resistance
WHERE IT CONNECTS
Typical Applications
⚡
Panel Wiring
Internal control panel, switchgear cabinet, PLC rack, and distribution board jumper circuits.
View Application →
🔌
Internal Equipment Wiring
Chassis wiring for commercial electronics, power supplies, and industrial apparatus.
View Application →
🔥
High-Temperature Wiring
Furnaces, extrusion ovens, aircraft engine compartments, and glass manufacturing.
View Application →
⚡
UPS & Battery Interconnection
Protected battery-bank and UPS/inverter links; assess DC fault current, terminals and voltage drop.
View Application →Select the cable construction to suit the circuit, operating conditions and installation.
INDUSTRY APPLICATIONS
Industries Served
STANDARDS & COMPLIANCE
Applicable Reference Standards
Manufactured in reference to applicable equipment wiring specifications including BS G 177 and IS 10241 Part 3.
Applicable Standard
BS G 177
Airframe and equipment electrical cable construction reference
Applicable Standard
IS 10241 Part 3
Aircraft electrical cables specification reference
TECHNICAL EXPLANATION
What is Uninyvin Cable?
Uninyvin is a high-performance electrical cable engineered with annealed tinned copper conductors, heat-resistant dielectric insulation, and a protective glass-fibre nylon braid for mission-critical power and control circuits.
🔌
Tinned Copper Conductor
Constructed with hot-dipped annealed tinned copper (ATC) flexible stranded wire. The tin coating prevents copper oxidation at elevated temperatures and eliminates galvanic corrosion in humid and corrosive environments.
🌡️
105°C HR-PVC Insulation
Insulated with premium Heat-Resistant PVC (HR-PVC) compound delivering dependable dielectric performance from −35°C to +105°C continuous operating temperature, with 600 V AC nominal working rating.
🛡️
Glass Braid & Nylon Protection
Protected by a dense woven glass-fibre braid that resists thermal melt-through, finished with an extruded transparent nylon sheath (U22–U12) or nylon braid with protective lacquer (U10–U0000) for superior abrasion resistance.
DIMENSIONAL & AMPACITY MATRIX
Uninyvin Gauge Schedule (U22 to U0000)
Confirmed conductor area, finished diameter limits, DC resistance, and current ratings across single cable and bundled installation schedules.
Scroll horizontally to view the complete gauge schedule.
| U-gauge | Conductor area (mm²) | Min. PVC thickness (mm) | Finished OD range (mm) | Max. DC resistance at 20°C (Ω/km) | Single cable (A) | 3-cable bundle (A) | 7-cable bundle (A) |
|---|---|---|---|---|---|---|---|
| U22 | 0.347 | 0.23 | 1.8 – 2.0 | 54.3 | 11 | 7 | 5 |
| U20 | 0.556 | 0.23 | 2.0 – 2.3 | 33.9 | 14 | 9 | 7 |
| U18 | 0.966 | 0.23 | 2.3 – 2.5 | 19.5 | 18 | 13 | 10 |
| U16 | 1.171 | 0.23 | 2.5 – 2.8 | 16.1 | 21 | 15 | 11 |
| U14 | 2.05 | 0.28 | 3.0 – 3.4 | 9.2 | 31 | 24 | 17 |
| U12 | 3.22 | 0.28 | 3.5 – 3.8 | 5.85 | 43 | 30 | 22 |
| U10 | 5.33 | 0.38 | 4.6 – 5.0 | 3.53 | 61 | 47 | 36 |
| U8 | 8.76 | 0.38 | 5.9 – 6.3 | 2.15 | 87 | 65 | 49 |
| U6 | 13.3 | 0.38 | 7.3 – 7.6 | 1.42 | 115 | 87 | 65 |
| U4 | 21.5 | 0.48 | 8.8 – 9.3 | 0.877 | 160 | 120 | 92 |
| U2 | 33.3 | 0.48 | 10.5 – 11.0 | 0.565 | 200 | 155 | 120 |
| U1 | 40.7 | 0.56 | 11.7 – 12.2 | 0.463 | 220 | 165 | 130 |
| U0 | 53.0 | 0.64 | 13.0 – 13.7 | 0.355 | 240 | 185 | — |
| U00 | 68.3 | 0.69 | 14.6 – 15.4 | 0.276 | 270 | 210 | — |
| U000 | 84.2 | 0.76 | 16.1 – 16.9 | 0.223 | 300 | 235 | — |
| U0000 | 109.0 | 0.79 | 17.9 – 18.7 | 0.173 | 350 | 270 | — |
OD = finished outside diameter. — = no current rating listed for this installation.
Note on Ampacity: Ratings based on 65°C ambient, 105°C conductor, 40°C temperature rise. Apply installation-specific grouping and enclosure derating factors. Nominal cable weights and specific packing reel schedules are verified via project-specific Guaranteed Technical Particulars (GTP).
OFFICIAL TECHNICAL DOCUMENTATION
Guaranteed Technical Particulars (GTP) — Uninyvin Cable
Download the official engineering GTP document (Doc ID: PER-GTP-UNYVIN-R02) detailing conductor bunching, braid carrier schedules, dielectric test voltages, and temperature limits.
CONFIRMED SPECIFICATIONS
Frequently Asked Questions: Uninyvin Cable
Common technical questions from electrical engineers, switchboard designers, and procurement managers regarding Uninyvin cable selection.
What is Uninyvin cable and what does the construction consist of?
Uninyvin cable is a specialized single-core electrical cable designed for elevated temperatures and harsh mechanical environments. Its construction consists of an annealed tinned copper (ATC) flexible stranded conductor, Heat-Resistant PVC (HR-PVC) primary insulation rated for 105°C, a dense protective glass-fibre braid, and an extruded transparent nylon sheath (gauges U22 to U12) or nylon braid with protective lacquer (gauges U10 to U0000).
How does Uninyvin cable differ from standard single-core PVC hook-up wire?
Standard hook-up wire uses bare copper strands and standard 70°C thermoplastic PVC without reinforcement. Uninyvin cable incorporates tinned copper strands that prevent galvanic corrosion and oxidation, 105°C heat-resistant dielectric insulation, and an exterior glass-fibre and nylon composite barrier that prevents melt-through, surface cut-through, and chemical attack.
How do I select the proper Uninyvin gauge (U22 to U0000) for my circuit?
Uninyvin sizing follows the British "U" gauge schedule ranging from U22 (0.347 mm²) for light instrumentation and control leads up to U0000 (109 mm²) for heavy battery connections and high-amperage power leads. Sizing should be selected based on continuous load current, permissible voltage drop, thermal grouping factor (single cable vs bundle), and installation ambient temperature.
What are the continuous temperature and voltage ratings of Uninyvin cable?
Peraton Uninyvin cables are rated for nominal operating voltages up to 600 V AC (rms) and continuous operating temperatures from -35°C to +105°C.
How can I request a project-specific Guaranteed Technical Particulars (GTP) document?
You can download the official GTP Revision R02 PDF directly from this page, or submit your specific gauge schedule, bill of quantities (BOQ), and project specifications through our Submit Enquiry portal for certified engineering sign-off.
RELATED CABLE DIVISIONS
Explore Related Technical Categories
CATEGORY DIRECTORY
Uninyvin Cables Category →
Browse all Uninyvin variants, technical schedule overview, and manufacturing options.
HIGH TEMPERATURE
Silicone Cable (+180°C) →
For continuous thermal duty exceeding 105°C in industrial furnaces and heating machinery.
CONTROL PANELS
Single Core Panel Wire →
Class 5 flexible copper wire for switchboard channels and standard panel wiring.
PRODUCT HUB
Cables and Wires Guide →
Complete overview of all six Peraton cable families with selection guidelines.
RELATED CABLE DESIGNS
Similar & Complementary Products