VFD Cables
Shielded EMC VFD / Variable Frequency Drive Cables
Symmetrical Power Conductors & Heavy EMC Screening for PWM Inverter Motor Drives
Technical Architecture & Procurement Specifications
Peraton shielded VFD cables are specifically engineered to withstand the harsh electrical conditions created by modern Variable Frequency Drives (VFDs) and Inverter-Duty Motors. Fast-switching IGBT drive outputs generate extreme voltage spikes, high-frequency harmonics, and capacitive cable charging currents that cause motor bearing fluting, insulation puncture, and severe electromagnetic interference (EMI) across plant control networks.
Constructed with XLPE insulation featuring low dielectric constant and high impulse dielectric strength, Peraton VFD cables withstand reflected wave voltage spikes up to twice the nominal drive bus voltage. Featuring symmetrical grounding architectures (3 power cores + 3 split ground conductors) and heavy dual shielding (copper tape or foil plus dense tinned copper braid), these cables attenuate common-mode noise and maintain plant EMC integrity. Engineered to tame inverter electrical stresses, our shielded VFD cables undergo 100% spark testing, transfer impedance verification, and insulation resistance testing to ensure complete protection for plant motors, bearings, and sensitive control equipment. Peraton works closely with electrical consultants, EPC contractors, and OEM panel builders across India, providing complete Guaranteed Technical Particulars (GTP), custom length reeling, and responsive technical procurement support for tender submissions.
Engineered Cables & Wires (1)
Each cable product is manufactured with defined conductor stranding, controlled insulation compounds, and standard quality testing.
VFD Cables
Frequently Asked Questions: VFD Cables
Why is standard PVC cable inadequate for VFD motor installations?
Standard PVC has high dielectric losses and lower impulse strength; under PWM drive switching, PVC insulation suffers capacitive heating, accelerated aging, and rapid breakdown from reflected voltage peaks.
What is the purpose of symmetrical split ground conductors in VFD cables?
Three symmetrical grounds placed in the cable interstices eliminate electromagnetic asymmetry, minimizing common-mode circulating currents and reducing shaft voltages that cause motor bearing failure.
What screening does Peraton incorporate on VFD cables?
Peraton applies a dual shielding system consisting of 100% aluminum-polyester tape coupled with a heavy tinned copper wire braid to provide superior low-transfer impedance across low and high radio frequencies.